FOB Price : Get a Price/Quote
Min.Order : 1 Piece(s)
Certification : CFDA,CE,CFS
Brand Name : DY-MED
Payment Terms : T/T,WesternUnion
brand name : DY-MED
certification : CFDA,CE,CFS
min.order : 1 Piece(s)
warranty : /
payment terms : T/T,WesternUnion
Packaging : /
Specification : /
place of origin : Hunan
Item | Technical Parameter |
Infusion Mode | Volume Mode, Time mode, Drug Mode, Bolus Mode, Drip Mode |
Rate Unit | Ml/h, volume/time, d/min |
IV Sets | Standard single use IV sets(20 and 60d/ml, with diameter 3.4~4.5mm) |
Flow Rate | 1.0ml/h~1200ml/h; 1.0d/min~400/min |
Increment | 1.0-99.9ml/h with 0.1ml/h; 100-1200ml/h with 1ml/h |
Flow Rate Deviation | <±5%(after calibration) |
VTBI | 0.1~9999ml |
Infused Volume | 0~999ml |
Time Setting | 1 min to 99h59min |
Purge Rate | 600ml/h, displaying purge volume |
KVO | 0.1ml/h~5.0ml/h, adjustable |
Keypad | Numeric Keypad, user friendly |
BOLUS Mode | Available for Bolus mode, flow rate adjustable |
Night Mode | Night mode, No operation for 5mins, LCD brightness lower automatically |
Occlusion Pressure Detection | Upstream and downstream pressure detection, detection range: 40-130Kpa, 0~9 levels adjustable, dynamic pressure value display |
Air bubble Detection | Ultrasonic detection, ≥50μL , Single bubble volume: 50~300μL , 0~9 levels adjustable |
Alarm &Volume | 0~9 levels adjustable |
Anti-reverse Function | Anti-reverse function on motor to prevent upstream |
IV Set Management | Open System, Can accept all kinds of IV Set after calibration |
Self-Testing | Self-Testing when start up and during infusing |
Audio and Visual Alarms | Air bubble, upstream occlusion, downstream occlusion, door open, infusion finish, standby time expired, battery low, battery low, battery empty, battery disengaged, AC Power disengaged, Motor error, pump error, pressure sensor error, parameter error, system abnormal. |
Screen | 3.2” Brightness LCD |
Power Supply | AC:100V~240V, 50Hz/60Hz,≤25VA |
Battery | Rechargeable Lithium battery: DC11.1V, 3000mAh, life:≥10 hours@25ml/h, displaying remaining battery |
Operation Condition | Temperature: 5℃~40℃, Relative humidity:20%~80%, Atmospheric pressure:70~106Kpa |
Transportation and Storage | Temperature: -20℃~55℃, Relative humidity:10%~95%, Atmospheric pressure:50~106Kpa |
Classification | Type CF, Class I, IPX3, ISO13485, CE, IEC60601 |
Ordinary verified
Business Type Manufacturer
Country / Region Hunan,China
Main Products Anesthesia Equipment, Infusion & Auxiliary, Hospital Bed, Home Health Equipment
Main Markets
brand name : DY-MED
certification :
fob price :
min.order : 1 Piece(s)
warranty : /
payment terms : T/T,WesternUnion
Packaing : /
Specification : /
Trademark : DY-MED
Production Capacity :
place of origin : Hunan
Manag Certifica : CFDA,CE,CFS
Item | Technical Parameter |
Infusion Mode | Volume Mode, Time mode, Drug Mode, Bolus Mode, Drip Mode |
Rate Unit | Ml/h, volume/time, d/min |
IV Sets | Standard single use IV sets(20 and 60d/ml, with diameter 3.4~4.5mm) |
Flow Rate | 1.0ml/h~1200ml/h; 1.0d/min~400/min |
Increment | 1.0-99.9ml/h with 0.1ml/h; 100-1200ml/h with 1ml/h |
Flow Rate Deviation | <±5%(after calibration) |
VTBI | 0.1~9999ml |
Infused Volume | 0~999ml |
Time Setting | 1 min to 99h59min |
Purge Rate | 600ml/h, displaying purge volume |
KVO | 0.1ml/h~5.0ml/h, adjustable |
Keypad | Numeric Keypad, user friendly |
BOLUS Mode | Available for Bolus mode, flow rate adjustable |
Night Mode | Night mode, No operation for 5mins, LCD brightness lower automatically |
Occlusion Pressure Detection | Upstream and downstream pressure detection, detection range: 40-130Kpa, 0~9 levels adjustable, dynamic pressure value display |
Air bubble Detection | Ultrasonic detection, ≥50μL , Single bubble volume: 50~300μL , 0~9 levels adjustable |
Alarm &Volume | 0~9 levels adjustable |
Anti-reverse Function | Anti-reverse function on motor to prevent upstream |
IV Set Management | Open System, Can accept all kinds of IV Set after calibration |
Self-Testing | Self-Testing when start up and during infusing |
Audio and Visual Alarms | Air bubble, upstream occlusion, downstream occlusion, door open, infusion finish, standby time expired, battery low, battery low, battery empty, battery disengaged, AC Power disengaged, Motor error, pump error, pressure sensor error, parameter error, system abnormal. |
Screen | 3.2” Brightness LCD |
Power Supply | AC:100V~240V, 50Hz/60Hz,≤25VA |
Battery | Rechargeable Lithium battery: DC11.1V, 3000mAh, life:≥10 hours@25ml/h, displaying remaining battery |
Operation Condition | Temperature: 5℃~40℃, Relative humidity:20%~80%, Atmospheric pressure:70~106Kpa |
Transportation and Storage | Temperature: -20℃~55℃, Relative humidity:10%~95%, Atmospheric pressure:50~106Kpa |
Classification | Type CF, Class I, IPX3, ISO13485, CE, IEC60601 |