Production introduction
Auto-Pure96/Auto-Pure48/Auto-Pure24 Nucleic Acid Purification System adopts magnetic bead separation technology, using 96×2.2ml Deep well plate and 96 magnetic rod’s tip (1,000ul reaction system)and 48×5ml Deep well plate and 24 magnetic rod’s tip (5,000ul reaction system) and 24×14ml Deep well plate and 24 magnetic rod’s tip (10,000ul reaction system). Combined with different kinds of magnetic bead nucleic acid extraction kits, it can operate 1-96 samples or 1-24 samples simultaneously and extract DNA and RNA rapidly in 30-60 minutes.
Features
1.Simple, intelligent operation
Built-in lighting LED lights, it can observe the running status of the instrument in real time.
The front cover can be opened for quick stop, which is convenient for reagent optimization and observation.
Intelligent operation with self-inspection, power protection function.
8-plate position automatic identification design. No manual adjustment required.
2.Multiple pollution control
Drip-proof plate design with software control magnetic beads drying mode, to prevent the liquid splashing in the experiment process.
Disposable consumables can eliminate the cross contamination between holes and batches.It has built-in disinfection function which can do regular UV disinfection.
3.Extension Internet
It can be controlled by phone app software to check the running status of the instrument in real time.
Thoroughly releasing manpower, remote monitoring.
4.High quality and rapid extraction
Auto-Pure 96 can process 96×1ml samples simultaneously.
The maximum sample size is 10ml.
It can effectively avoid the influence of human factors on the experiment.
5.Open software design, software can be edited freely
Room temperature + 5℃~120 ℃, accurate temperature control.
Single machine can do program editing.
The software has complete functions and is suitable for all kinds of magnetic bead reagents.
Diverse binding and magnetic absorption modes, which is conducive to reagent optimization.
6.Reliable structure and stable operation
Auto Pure96/48/24 adopts lead screw drive to realize lifting movement with high precision.
Patent structure design with center rotary table which makes it occupy less area.
Patent design for automatic loading and unloading structure of magnetic rod tip comb, which guarantee stability and liability. (Success rate>99.99%)
Parameters
Turnplate design with small occupied space and stable operation.
Patent structure of magnetic rod sleeve loading and unloading, more stable and reliable.