S. typhoid/S. Para typhi Ag Rapid Test Device (Feces)

FOB Price : Get a Price/Quote

Min.Order : 1000 Piece(s)

Certification : ISO13485,CE

Brand Name : Funworld

Payment Terms : T/T,D/P

share :

product information

  • brand name : Funworld

  • certification : ISO13485,CE

  • min.order : 1000 Piece(s)

  • warranty : 2 years

  • payment terms : T/T,D/P

  • Packaging : Standard Export Carton

  • Specification : 20 Tests/ box

  • place of origin : Zhejiang

product description

The S. typhoid/S. Para typhi Ag Rapid Test Device (Feces) is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing S.typhoid/S. Para typhi antibody conjugated with colloid gold, 2) a nitrocellulose membrane strip containing two test bands (S. typhoid/S. Para typhi bands) and a control band (C band). The S. typhoid band is pre-coated with monoclonal anti- S. typhoid for the detection of S. typhoid Ag, S. Para typhi band is pre-coated with reagents for the detection of S. Para typhi Ag , and the C band is pre-coated with goat anti mouse IgG.
When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. S. typhoid Ag if present in the patient specimen will bind to the S. typhoid Ab conjugates. The immunocomplex is then captured on the membrane by the pre-coated S. typhoid antibody, forming a burgundy colored S. typhoid band, indicating a S. typhoid positive test result. S. Para typhi Ag if present in the patient specimen will bind to the S. Para typhi Ab conjugates. The immunocomplex is then captured by the pre-coated S. Para typhi Ab on the membrane, forming a burgundy colored S. Para typhi Ab band, indicating a S. Para typhi Ab positive test result. Absence of any test bands suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti Mouse IgG/Mouse IgG-gold conjugate regardless of the color development on any of the test bands.
Otherwise, the test result is invalid and the specimen must be retested with another device.

People who viewed this also viewed

  • HBsAg Rapid Test Device (Whole Blood /Serum/ Plasma)

    FOB Price :

    Min.Order : 1000 Piece(s)

  • HIV Ab/Ag Rapid Test Device (WB/S/P)

    FOB Price :

    Min.Order : 1000 Piece(s)

  • Dengue IgG/IgM+Ns1 Combo Test Device (Whole Blood/Serum/Plasma)

    FOB Price :

    Min.Order : 1000 Piece(s)

  • Dengue Ns1 Test Device (Whole Blood/Serum/Plasma)

    FOB Price :

    Min.Order : 1000 Piece(s)

  • HCV Rapid Test Device (Whole Blood/Serum/Plasma)

    FOB Price :

    Min.Order : 1000 Piece(s)

S. typhoid/S. Para typhi Ag Rapid Test Device (Feces)
share :

product information

product description

The S. typhoid/S. Para typhi Ag Rapid Test Device (Feces) is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing S.typhoid/S. Para typhi antibody conjugated with colloid gold, 2) a nitrocellulose membrane strip containing two test bands (S. typhoid/S. Para typhi bands) and a control band (C band). The S. typhoid band is pre-coated with monoclonal anti- S. typhoid for the detection of S. typhoid Ag, S. Para typhi band is pre-coated with reagents for the detection of S. Para typhi Ag , and the C band is pre-coated with goat anti mouse IgG.
When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. S. typhoid Ag if present in the patient specimen will bind to the S. typhoid Ab conjugates. The immunocomplex is then captured on the membrane by the pre-coated S. typhoid antibody, forming a burgundy colored S. typhoid band, indicating a S. typhoid positive test result. S. Para typhi Ag if present in the patient specimen will bind to the S. Para typhi Ab conjugates. The immunocomplex is then captured by the pre-coated S. Para typhi Ab on the membrane, forming a burgundy colored S. Para typhi Ab band, indicating a S. Para typhi Ab positive test result. Absence of any test bands suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti Mouse IgG/Mouse IgG-gold conjugate regardless of the color development on any of the test bands.
Otherwise, the test result is invalid and the specimen must be retested with another device.

Recommend

Join Free

Create New Account

Leave your contact information for the suppliers. If you're our member, Please Sign In to use your account information.

Sign in