Hangzhou Funworld Biotech Co.,Ltd

Hangzhou Funworld Biotech Co.,Ltd

Zhejiang,China

Hangzhou Funworld Biotech Co.,Ltd

Zhejiang,China

Hangzhou Funworld Biotech Co.,Ltd
favorite supplier

Hangzhou Funworld Biotech Co.,Ltd

Zhejiang,China

Scan QR code

Access to mobile station

Clear All
Alternate Text

Typhoid IgG/IgM Rapid Test Device (Whole Blood/Serum/Plasma)

FOB Price : Get a Price/Quote

Min.Order : 1000 Piece(s)

Certification : ISO13485,CE

Brand Name : Funworld

Payment Terms : T/T,D/P

share :

product information

  • brand name : Funworld

  • certification : ISO13485,CE

  • min.order : 1000 Piece(s)

  • warranty : 2 years

  • payment terms : T/T,D/P

  • Packaging : Standard Export Carton

  • Specification : 25 Tests/ box

  • place of origin : Zhejiang

product description

The Typhoid IgG/IgM Rapid Test Device is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing recombinant S. typhoid H antigen and O antigen conjugated with colloid gold (Typhoid conjugates) and rabbit IgG‐gold conjugates, 2) a nitrocellulose membrane strip containing two test bands (IgG and IgM bands) and a control band (C band). The IgM band is pre‐coated with monoclonal anti‐human IgM for the detection of IgM anti‐S. typhi, IgG band is pre‐coated with reagents for the detection of IgG anti‐S. typhi , and the C band is pre‐coated with goat anti rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. Anti‐S. typhi IgM if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured on the membrane by the pre‐coated anti‐human IgM antibody, forming a burgundy colored IgM band, indicating a S. typhi IgM positive test result.
Anti‐S. typhi IgG if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured by the pre‐coated reagents on the membrane, forming a burgundy colored IgG band, indicating a S. typhi IgG positive test result. Absence of any test bands suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit IgG/rabbit IgG‐gold conjugate regardless of the color development on any of the test bands.
Otherwise, the test result is invalid and the specimen must be retested with another device.

People who viewed this also viewed

  • fFN rapid test Device (Vaginal secretion)

    FOB Price :

    Min.Order : 1000 Piece(s)

  • Typhoid Ag Rapid Test Device (Feces)

    FOB Price :

    Min.Order : 1000 Piece(s)

  • Respiratory syncytial virus Antigen Rapid Test Device(Nasopharyngeal swabs/ Nasal swab)

    FOB Price :

    Min.Order : 1000 Piece(s)

  • Human Fecal Occult Blood (FOB) Rapid Test Device (Feces)

    FOB Price :

    Min.Order : 1000 Piece(s)

  • H. Pylori Ag Rapid Test Strip (Feces)

    FOB Price :

    Min.Order : 1000 Piece(s)

Typhoid IgG/IgM Rapid Test Device (Whole Blood/Serum/Plasma)
share :

product information

product description

The Typhoid IgG/IgM Rapid Test Device is a lateral flow chromatographic immunoassay. The test cassette consists of: 1) a burgundy colored conjugate pad containing recombinant S. typhoid H antigen and O antigen conjugated with colloid gold (Typhoid conjugates) and rabbit IgG‐gold conjugates, 2) a nitrocellulose membrane strip containing two test bands (IgG and IgM bands) and a control band (C band). The IgM band is pre‐coated with monoclonal anti‐human IgM for the detection of IgM anti‐S. typhi, IgG band is pre‐coated with reagents for the detection of IgG anti‐S. typhi , and the C band is pre‐coated with goat anti rabbit IgG. When an adequate volume of test specimen is dispensed into the sample well of the cassette, the test specimen migrates by capillary action across the test cassette. Anti‐S. typhi IgM if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured on the membrane by the pre‐coated anti‐human IgM antibody, forming a burgundy colored IgM band, indicating a S. typhi IgM positive test result.
Anti‐S. typhi IgG if present in the patient specimen will bind to the Typhoid conjugates. The immunocomplex is then captured by the pre‐coated reagents on the membrane, forming a burgundy colored IgG band, indicating a S. typhi IgG positive test result. Absence of any test bands suggests a negative result. The test contains an internal control (C band) which should exhibit a burgundy colored band of the immunocomplex of goat anti rabbit IgG/rabbit IgG‐gold conjugate regardless of the color development on any of the test bands.
Otherwise, the test result is invalid and the specimen must be retested with another device.

Recommend

Join Free

Create New Account

Leave your contact information for the suppliers. If you're our member, Please Sign In to use your account information.

Sign in